dc.identifier.citationDolgun, G.K.; Güler, O.V.; Georgiev, A.G.; Keçebaş, A. Experimental Investigation of a Concentrating Bifacial Photovoltaic/Thermal Heat Pump System with a Triangular Trough. Energies 2023, 16, 649. https://doi.org/10.3390/en16020649en_US
dc.identifier.issn19961073
dc.identifier.urihttps://doi.org/10.3390/en16020649
dc.identifier.urihttps://hdl.handle.net/20.500.12809/10517
dc.description.abstractThe heat absorbed by the heat transfer fluid for cooling a concentrated photovoltaic thermal (CPVT) solar collector can be used for purposes such as residential heating and cooking. Because of the combined production of heat and power, these systems are proposed for individual or commercial use in rural areas. In this study, a hybrid system was proposed to increase the electrical efficiency of the system. Experiments were conducted in winter conditions. Two operational modes were compared, namely a CPVT system with HP (HP-CPVT) and without HP (CPVT). The evaporator of the heat pump was settled inside the triangular trough receiver. The effects of cooling the PV system with a heat pump in the bifacial CPVT system on the electrical and thermal energy efficiencies were investigated. The electricity and thermal energy efficiencies of the CPVT system were calculated as 12.54% and 38.37% in the HP-CPVT system, respectively, and 10.05% and 81.97% in the CPVT system, respectively. The electrical exergy efficiencies of the CPVT system with and without HP were 14.65% and 10.73%, respectively. The thermal exergy efficiencies of the CPVT system with and without HP were 82.47% and 85.63%, respectively. The thermal heat obtained from the HP-CPVT system can be used for heating needs. Thus, the bifacial HP-CPVT system was an example of the micro-CHP system.en_US
dc.item-language.isoengen_US
dc.publisherMDPIen_US
dc.relation.isversionof10.3390/en16020649en_US
dc.item-rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectCombined heat and poweren_US
dc.subjectCPVTen_US
dc.subjectHeat pumpen_US
dc.subjectParabolic triangular troughen_US
dc.titleExperimental Investigation of a Concentrating Bifacial Photovoltaic/Thermal Heat Pump System with a Triangular Troughen_US
dc.item-typearticleen_US
dc.contributor.departmentMÜ, Teknoloji Fakültesi, Enerji Sistemleri Mühendisliği Bölümüen_US
dc.contributor.authorID0000-0002-6219-6016en_US
dc.contributor.authorID0000-0003-4809-2461en_US
dc.contributor.authorID0000-0002-0910-1743en_US
dc.contributor.institutionauthorKaraca Dolgun, Gülşah
dc.contributor.institutionauthorGüler, Onur Vahip
dc.contributor.institutionauthorKeçebaş, Ali
dc.identifier.volume16en_US
dc.identifier.issue2en_US
dc.relation.journalEnergiesen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US


Bu öğenin dosyaları:

Thumbnail

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster