Basit öğe kaydını göster

dc.contributor.authorÖzden, Fatih
dc.contributor.authorÖzkeskin, Mehmet
dc.contributor.authorEkici, Ece
dc.contributor.authorYüceyar, Nur
dc.date.accessioned2023-08-22T10:56:05Z
dc.date.available2023-08-22T10:56:05Z
dc.date.issued2023en_US
dc.identifier.citationÖzden, F., Özkeskin, M., Ekici, E. et al. Agreement between video-based clinician-rated tools and patient-reported outcomes on gait assessment in individuals with multiple sclerosis. Neurol Sci (2023). https://doi.org/10.1007/s10072-023-06983-7en_US
dc.identifier.issn15901874
dc.identifier.otherPubMed ID: 37535127
dc.identifier.urihttps://doi.org/10.1007/s10072-023-06983-7
dc.identifier.urihttps://hdl.handle.net/20.500.12809/10902
dc.description.abstractPurpose: To our knowledge, no studies compared the video-clinician-based tools and patient-reported questionnaires in assessing gait and balance in people with MS (pwMS). The present study investigated the correlation and agreement between video-clinician-based objective measurement tools and patient-reported outcome measures (PROMs) in gait and balance evaluation. Methods: A prospective cross-sectional study was conducted with 55 pwMS. Video analysis-based gait was evaluated by the Tinetti Gait Assessment (TGA), Gait Assessment and Intervention Tool (GAIT), and Functional Ambulation Classification Scale (FACS) by the clinician. Participants’ self-reported gait and balance were assessed with the Multiple Sclerosis Walking Scale-12 (MSWS-12) and Activity-Specific Balance Confidence Scale (ABC). Results: There was a moderate positive correlation between ABC with TGA and FACS (r 1: 0.552, r 2: 0.510, p < 0.001). ABC was strongly correlated with GAIT (r: − 0.652, p < 0.001). A moderate positive correlation was observed between MSWS-12 with TGA and FACS (r 1: − 0.575, r 2: − 0.524, p < 0.001). In addition, there was a strong positive correlation between MSWS-12 and GAIT (r: − 0.652, p < 0.001). Clinician-rated tools and PROMs were within the agreement limits regarding the unstandardized beta values p < 0.001). Conclusions: Clinician-based gait and balance tools demonstrate consistent results with PROMs in pwMS. Considering the low cost and practical use of PROMs, in cases where video-based clinician-based measurements cannot be provided (time, space, and technical inadequacies), questionnaires can provide concordant results at moderate and severe levels compared with objective tools.en_US
dc.item-language.isoengen_US
dc.publisherSpringer-Verlag Italia s.r.l.en_US
dc.relation.isversionof10.1007/s10072-023-06983-7en_US
dc.item-rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectConcordanceen_US
dc.subjectMultiple sclerosisen_US
dc.subjectQuestionnairesen_US
dc.subjectWalkingen_US
dc.titleAgreement between video-based clinician-rated tools and patient-reported outcomes on gait assessment in individuals with multiple sclerosisen_US
dc.item-typearticleen_US
dc.contributor.departmentMÜ, Köyceğiz Sağlık Hizmetleri Meslek Yüksekokulu, Sağlık Bakım Hizmetleri Bölümüen_US
dc.contributor.authorID0000-0001-6593-3758en_US
dc.contributor.institutionauthorÖzden, Fatih
dc.relation.journalNeurological Sciencesen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US


Bu öğenin dosyaları:

Thumbnail

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster