Anatomical and functional changes after aortic valve replacement with different sizes of mechanical valves

Thumbnail

Göster/Aç

Tam metin / Full text (93.52Kb)

Tarih

2018

Yazar

İlhan, Gökhan
Bozok, Şahin
Özpak, Berkan
Kara, Hakan
Yazman, Serkan
Bayrak, Serdar
Gürbüz, Ali

Üst veri

Tüm öğe kaydını göster

Özet

Objective: To date. there is no consensus on the selection of type and size of prosthetic valve for aortic valve replacement (AVR). The aim of this study was to compare anatomical and functional changes occurring in the left ventricle after AVR with different sizes of mechanical valves. Methods: A total of 92 patients with serious aortic valve stenosis. who underwent AVR between March 2001 and June 2008 using mechanical valves of different sizes. were retrospectively analysed. The sizes of mechanical valves v ere 19, 21, 23 and 25 mm. All patients were assessed pre-operatively and at six months and in first, third and fifth years postoperatively. The left ventricle was assessed with electrocardiography, echocardiography and telecardiography and compared in the four patient groups, constituted according to the mechanical valve size used. Results: In all groups, left ventricular mass and mass index. transvalvular aortic gradient. thicknesses of the interventricular septum and posterior wall and left ventricular end-systolic and end-diastolic diameters had decreased significantly post surgery. Left ventricular ejection fraction and exercise capacity had increased significantly (p < 0.001). The most noteworthy anatomical and functional improvements were seen in patients who had received 23- and 25-mm mechanical valves. Conclusion: Mechanical valve e replacement should not be performed with small size Ayes because of the higher residual gradient.

Kaynak

Cardiovascular Journal of Africa

Cilt

29

Sayı

6

Bağlantı

https://doi.org/10.5830/CVJA-2018-037
https://hdl.handle.net/20.500.12809/1301

Koleksiyonlar

  • Cerrahi Tıp Bilimleri Bölümü Koleksiyonu [543]
  • PubMed İndeksli Yayınlar Koleksiyonu [2082]
  • Scopus İndeksli Yayınlar Koleksiyonu [6219]
  • WoS İndeksli Yayınlar Koleksiyonu [6466]



DSpace software copyright © 2002-2015  DuraSpace
İletişim | Geri Bildirim
Theme by 
@mire NV
 

 




| Politika | Rehber | İletişim |

DSpace@Muğla

by OpenAIRE
Gelişmiş Arama

sherpa/romeo

Göz at

Tüm DSpaceBölümler & KoleksiyonlarTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTüre GöreDile GöreBölüme GöreKategoriye GöreYayıncıya GöreErişim ŞekliKurum Yazarına GöreBu KoleksiyonTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTüre GöreDile GöreBölüme GöreKategoriye GöreYayıncıya GöreErişim ŞekliKurum Yazarına Göre

Hesabım

GirişKayıt

DSpace software copyright © 2002-2015  DuraSpace
İletişim | Geri Bildirim
Theme by 
@mire NV
 

 


|| Politika || Rehber|| Yönerge || Kütüphane || Muğla Sıtkı Koçman Üniversitesi || OAI-PMH ||

Muğla Sıtkı Koçman Üniversitesi, Muğla, Türkiye
İçerikte herhangi bir hata görürseniz, lütfen bildiriniz:

Creative Commons License
Muğla Sıtkı Koçman Üniversitesi Institutional Repository is licensed under a Creative Commons Attribution-NonCommercial-NoDerivs 4.0 Unported License..

DSpace@Muğla:


DSpace 6.2

tarafından İdeal DSpace hizmetleri çerçevesinde özelleştirilerek kurulmuştur.