• Türkçe
    • English
  • English 
    • Türkçe
    • English
  • Login
View Item 
  •   DSpace@Muğla
  • Araştırma Çıktıları | TR-Dizin | WoS | Scopus | PubMed
  • WoS İndeksli Yayınlar Koleksiyonu
  • View Item
  •   DSpace@Muğla
  • Araştırma Çıktıları | TR-Dizin | WoS | Scopus | PubMed
  • WoS İndeksli Yayınlar Koleksiyonu
  • View Item
JavaScript is disabled for your browser. Some features of this site may not work without it.

Electro-nano Diagnostic Platforms for Simultaneous Detection of Multiple Cancer Biomarkers

Thumbnail

View/Open

Tam metin / Full text (1.392Mb)

Date

2017

Author

Kalyoncu, Dorukhan
Tepeli, Yudum
Kırgöz, Umut Can
Buyraç, Arda
Anık, Ülkü

Metadata

Show full item record

Abstract

In this study, a bimetallic nanomaterial-based electrochemical immunosensor was developed for the detection of carcinoembryonic antigen (CEA) and vascular endothelial growth factor (VEGF) cancer biomarkers at the same time. CEA and VEGF biomarkers are indicators for colon and breast cancers and stomach cancers, respectively. During the study, gold nanoparticle (AuNp), lead nanoparticle (PbNp), copper nanoparticle (CuNp) and magnetic gamma iron(III)oxide (Fe2O3 Np) were synthesized, characterized and used together for the first time in the structure of an electrochemical biosensor based on anti-CEA and anti-VEGF. For this purpose, Au SPE based sandwich immunosensor was fabricated by using labeled anti-CEA (labeled with Pb+2) and labeled anti-VEGF (labeled with Cu+2). As a result, CEA and VEGF biomarkers were detected following the oxidation peaks of label metals (Pb+2 and Cu+2) by using differential pulse voltammetry. After the experimental parameters were optimized, the linear range was found in the concentration range between 25ng/mL and 600ng/mL with the relative standard deviation (RSD) value of (n=3 for 600ng/mL) 3.33% and limit of detection (LOD) value of 4.31ng/mL for CEA biomarker. On the other hand, the linear range was found in the concentration range between 0.2ng/mL and 12.5ng/mL with the RSD value of (n=3 for 12.5ng/mL) 5.31% and LOD value of 0.014ng/mL for VEGF biomarker. Lastly, sample application studies for synthetic plasma sample and interference studies with dopamine, ascorbic acid, BSA, cysteine and IgG were carried out.

Source

Electroanalysis

Volume

29

Issue

12

URI

https://doi.org/10.1002/elan.201700556
https://hdl.handle.net/20.500.12809/1763

Collections

  • Kimya Bölümü Koleksiyonu [352]
  • WoS İndeksli Yayınlar Koleksiyonu [6466]



DSpace software copyright © 2002-2015  DuraSpace
Contact Us | Send Feedback
Theme by 
@mire NV
 

 




| Policy | Guide | Contact |

DSpace@Muğla

by OpenAIRE
Advanced Search

sherpa/romeo

Browse

All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsTypeLanguageDepartmentCategoryPublisherAccess TypeInstitution AuthorThis CollectionBy Issue DateAuthorsTitlesSubjectsTypeLanguageDepartmentCategoryPublisherAccess TypeInstitution Author

My Account

LoginRegister

DSpace software copyright © 2002-2015  DuraSpace
Contact Us | Send Feedback
Theme by 
@mire NV
 

 


|| Policy || Guide|| Instruction || Library || Muğla Sıtkı Koçman University || OAI-PMH ||

Muğla Sıtkı Koçman University, Muğla, Turkey
If you find any errors in content, please contact:

Creative Commons License
Muğla Sıtkı Koçman University Institutional Repository is licensed under a Creative Commons Attribution-NonCommercial-NoDerivs 4.0 Unported License..

DSpace@Muğla:


DSpace 6.2

tarafından İdeal DSpace hizmetleri çerçevesinde özelleştirilerek kurulmuştur.