An evaluation of thyrotoxic autoimmune thyroiditis patients with triplex Doppler ultrasonography
Date
2014Author
Karakas, OmerKarakas, Ekrem
Cullu, Nesat
Demir, Yusuf
Kucukyavas, Yasin
Surucu, Erdem
Igci, Enis
Metadata
Show full item recordAbstract
Objective: This study aimed to investigate the usefulness of blood flow parameters obtained from STA and CCA with Triplex Doppler ultrasonography (TDU) on patients with thyrotoxicosis. Materials and methods: This cross-sectional study included consecutive 24 patients with thyrotoxicosis and 18 healthy controls. The thyroid gland blood flow parameters were evaluated with TDU. Results: The thyroid volumes and FT3, TRAb, 4-h and 24-h radioactive iodine uptake (RAIU) levels of Group 1 were significantly high compared to those of Group 2. The thyroid volumes and FT3, FT4 and TSH levels of both Group 1 and Group 2 showed a statistically significant difference compared to Group 3. STA-PSV values for Group 1, Group 2 and Group 3 were 138 cm/s, 54 cm/s and 37 cm/s, respectively. STA-EDV values for these groups were 60 cm/s, 25 cm/s and 15 cm/s, respectively. PSVR values for these groups were 1.01, 0.45, 0.34 cm/s, respectively. EDVR values for these groups were 1.29, 0.70 and 0.49 cm/s, respectively. In Group 1, STA-PSV, STA-EDV, PSVR and EDVR values were significantly high compared to those of Group 2. RAIU levels showed a significant positive correlation with the STA-PSV, STA-EDV and PSVR. Conclusion: The thyroid gland blood flow parameters may be used in clinical diagnosis of patients with thyrotoxicosis. (C) 2014 Elsevier Inc. All rights reserved.