• Türkçe
    • English
  • Türkçe 
    • Türkçe
    • English
  • Giriş
Öğe Göster 
  •   DSpace@Muğla
  • Araştırma Çıktıları | TR-Dizin | WoS | Scopus | PubMed
  • WoS İndeksli Yayınlar Koleksiyonu
  • Öğe Göster
  •   DSpace@Muğla
  • Araştırma Çıktıları | TR-Dizin | WoS | Scopus | PubMed
  • WoS İndeksli Yayınlar Koleksiyonu
  • Öğe Göster
JavaScript is disabled for your browser. Some features of this site may not work without it.

The effects of vital dyes on mechanical properties of the human anterior lens capsule

Tarih

2020

Yazar

Simsek, Cem
Gokmen, Onur

Üst veri

Tüm öğe kaydını göster

Özet

Purpose: The purpose of this study was to evaluate the mechanical effects of vital dyes on the anterior lens capsule via the nanoindentation method. Methods: Twenty anterior lens capsules of 20 different patients were dissected into four equal fragments. Each fragment was stained separately with dyes for intraocular surgeries, such as trypan blue 0.06% (TB), brilliant blue 0.025% (BB), and indocyanine green 0.05% (ICG), for 1 min. The remaining fragment was assessed as an untreated control group. The alterations on the mechanical characteristics of the anterior lens capsule were evaluated using a nanoindentation testing device with Oliver-Pharr and Martens hardness methods. Results: The mean values of elasticity were 7.842 +/- 0.55 GPa for capsules fragments stained with TB (P < 0.05), 8.407 +/- 0.82 GPa for capsules fragments stained with BB (P < 0.05), 8.557 +/- 0.60 GPa for ICG (P < 0.05), and 6.09 +/- 0.57 GPa for the untreated control group. The mean values of stiffness were 299.7 +/- 47 MPa for TB (P < 0.05), 317.9 +/- 34 MPa for BB (P < 0.05), 331.8 +/- 48 MPa for ICG (P < 0.05), and 229.85 +/- 44 MPa for the untreated control group. The elasticity of the capsules statistically decreased in comparison to the control group, and the capsule stiffness showed a statistically significant increase in comparison to the untreated controls. Conclusion: The mechanical characteristics of the human anterior lens capsule were affected in association with the alterations in the elasticity and stiffness properties of the capsule as a result of exposure to three different dyes.

Kaynak

Indian Journal of Ophthalmology

Cilt

68

Sayı

1

Bağlantı

https://doi.org/10.4103/ijo.IJO_285_19
https://hdl.handle.net/20.500.12809/639

Koleksiyonlar

  • PubMed İndeksli Yayınlar Koleksiyonu [2082]
  • Scopus İndeksli Yayınlar Koleksiyonu [6219]
  • WoS İndeksli Yayınlar Koleksiyonu [6466]



DSpace software copyright © 2002-2015  DuraSpace
İletişim | Geri Bildirim
Theme by 
@mire NV
 

 




| Politika | Rehber | İletişim |

DSpace@Muğla

by OpenAIRE
Gelişmiş Arama

sherpa/romeo

Göz at

Tüm DSpaceBölümler & KoleksiyonlarTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTüre GöreDile GöreBölüme GöreKategoriye GöreYayıncıya GöreErişim ŞekliKurum Yazarına GöreBu KoleksiyonTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTüre GöreDile GöreBölüme GöreKategoriye GöreYayıncıya GöreErişim ŞekliKurum Yazarına Göre

Hesabım

GirişKayıt

DSpace software copyright © 2002-2015  DuraSpace
İletişim | Geri Bildirim
Theme by 
@mire NV
 

 


|| Politika || Rehber|| Yönerge || Kütüphane || Muğla Sıtkı Koçman Üniversitesi || OAI-PMH ||

Muğla Sıtkı Koçman Üniversitesi, Muğla, Türkiye
İçerikte herhangi bir hata görürseniz, lütfen bildiriniz:

Creative Commons License
Muğla Sıtkı Koçman Üniversitesi Institutional Repository is licensed under a Creative Commons Attribution-NonCommercial-NoDerivs 4.0 Unported License..

DSpace@Muğla:


DSpace 6.2

tarafından İdeal DSpace hizmetleri çerçevesinde özelleştirilerek kurulmuştur.