Özet
Generation of very short pulses with a pulse width in the order of a few nanoseconds or less is a requirement for an UWB communications system. A pulse generator circuit based on the step-recovery effect of an RF transistor has been designed for the 0-960-MHz UWB system, and is presented in this paper. The pulse generator includes a linear RF amplifier with common-emitter topology and a high-pass filter following the amplifier. Input of the RF amplifier is driven by a clock signal provided by a function generator. Amplifier output includes positive amplitude and negative amplitude pulses due to rising and falling edges of the collector-emitter voltage of the transistor, respectively. Amplifier output is then fed to a high-pass filter. Low-frequency transitions are further filtered out, and the output of the high-pass filter is a pulse train consisting of very short pulses. The pulse width has been measured as about 2.5 ns using a 300-MHz digital oscilloscope. Bir UWB haberleşme sistemi için, darbe süresi birkaç nanosaniye seviyesinde veya daha az olan darbelerin üretilmesi bir gerekliliktir. Bir RF tranzistörün aşamalı-toparlanma etkisine dayalı bir darbe üreten devre 0-960-MHz UWB sistemi için tasarlanmıştır ve bu makalede sunulmaktadır. Darbe üreten devre ortak-emetör konfigürasyonlu doğrusal bir RF kuvvetlendirici ve kuvvetlendiriciyi izleyen bir yüksek-geçiren filtreden meydana gelmektedir. RF kuvvetlendiricinin girişi bir fonksiyon üreteci tarafından sağlanan bir saat işareti ile sürülmektedir. Kuvvetlendirici çıkışında, tranzistörün kollektör-emetör uçları arasındaki gerilimin yükselen ve inen kenarlarından kaynaklanan sırasıyla pozitif genlikli ve negatif genlikli darbeler vardır. Kuvvetlendirici çıkışı daha sonra bir yüksek-geçiren filtreye beslenir. Düşük frekanslı işaretler yüksek-geçiren filtre tarafından yeniden süzülür. Filtrenin çıkışı çok kısa süreli darbelerden meydana gelen bir darbe dizisidir. Darbe genişliği, 300-MHz'lik bir sayısal osiloskop kullanılarak 2.5 ns civarında ölçülmüştür.
Kaynak
Mugla Journal of Science and TechnologyCilt
4Sayı
1Bağlantı
https://doi.org/10.22531/muglajsci.422644https://app.trdizin.gov.tr//makale/TWpreU56QXdNQT09
https://hdl.handle.net/20.500.12809/6906
Koleksiyonlar
İlgili Öğeler
Başlık, yazar, küratör ve konuya göre gösterilen ilgili öğeler.
-
General Aspects of Recreational Angling and Some Estimations on Catch Amounts in Turkey
Soykan, Ozan; Cerim, Hasan (2018)Some simple approaches make easy to see problems that lie at the centre of the phenomenon. Contrary to expectations of outputs at the decision given may originate from lack of this simple approaches. From this point of ... -
Prizmatik Sıvı Tanklarında oluşan Sismik Çalkalanmaların SPH Yöntemiyle İncelenmesi
Yazıcı, Gökhan; Güray, Ersan; Aksel, Murat (2018)Bu çalışmada, yatay yönde yer sarsıntısına maruz kalan prizmatik bir tankta gerçekleşen çalkalanma modellemesi düzgünleştirilmiş parçacık hidrodinamiği yöntemiyle (SPH) gerçekleştirilmiştir. SPH yöntemi sonuçları bir deney ... -
Antımıcrobıal Actıvıty of Clementıne Peel Essentıal Oıl Wıth Its Cytotoxıc And in Vıtro Wound Healıng Potentıal on Nıh-3t3 Fıbroblast Cells
Baygar, Tuba; Saraç, Nurdan (2018)Citrus essential oils has many area of use such as skin and hair care, insomnia, improving digestion, and boosting immune system. The present study is aimed to determine the biological activities of clementine (Citrus ...