• Türkçe
    • English
  • Türkçe 
    • Türkçe
    • English
  • Giriş
Öğe Göster 
  •   DSpace@Muğla
  • Araştırma Çıktıları | TR-Dizin | WoS | Scopus | PubMed
  • WoS İndeksli Yayınlar Koleksiyonu
  • Öğe Göster
  •   DSpace@Muğla
  • Araştırma Çıktıları | TR-Dizin | WoS | Scopus | PubMed
  • WoS İndeksli Yayınlar Koleksiyonu
  • Öğe Göster
JavaScript is disabled for your browser. Some features of this site may not work without it.

Centri-Voltammetric Folic Acid Detection

Tarih

2020

Yazar

Buyuksunetci, Yudum Tepeli
Hakli, Ozgul
Anık, Ülkü

Üst veri

Tüm öğe kaydını göster

Özet

The need for practical detection of folic acid (FA) has been increased day by day. For this reason in this work, a two steps electroanalytical technique, centri-voltammetry was utilized for FA detection for the first time. In order to get rid of the slow electrode kinetics of FA oxidation, the working electrode was modified with graphene-Pt hibrid nanomaterial. Also for increasing the sensitivity, 1-Chloro-2-[2-(2-methoxyethoxy) ethoxy]ethane (TEG-Cl) and 1,2-di{2-[2-(2-methoxyethoxy)ethoxy] ethoxy}-4-nitrobenzene (4NC-NO2) was used as a carrier material. After the characterization of graphene-Pt hybrid nanomaterial, experimental parameters like, 4NC-NO2 amount, adsorption time, centri-voltammetric parameters like centrifuge time and speed were optimized. After that, analytical characteristics such as linear range, relative standard deviation (R.S.D), limit of detection (LOD) and limit of quantification (LOQ) values were found. In this manner, linear range was obtained for FA between 1.0 mu M-1000 mu M with the equations of y=0.0108x+1.0459 (R-2=0.9977). R.S.D value was calculated for 0.83 mM FA (n=3) as 1.86 % while LOD and LOQ values were found as 1.00 mu M and 3.34 mu M respectively. After the examination of interference effect of substances like ascorbic acid and uric acid, established centri-voltammetric technique was enforced for FA detection in pharmateutical tablets. As a result, the recovery value was calculated as 96.4 %.

Kaynak

Electroanalysis

Cilt

32

Sayı

3

Bağlantı

https://doi.org/10.1002/elan.201900582
https://hdl.handle.net/20.500.12809/804

Koleksiyonlar

  • Scopus İndeksli Yayınlar Koleksiyonu [6219]
  • WoS İndeksli Yayınlar Koleksiyonu [6466]



DSpace software copyright © 2002-2015  DuraSpace
İletişim | Geri Bildirim
Theme by 
@mire NV
 

 




| Politika | Rehber | İletişim |

DSpace@Muğla

by OpenAIRE
Gelişmiş Arama

sherpa/romeo

Göz at

Tüm DSpaceBölümler & KoleksiyonlarTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTüre GöreDile GöreBölüme GöreKategoriye GöreYayıncıya GöreErişim ŞekliKurum Yazarına GöreBu KoleksiyonTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTüre GöreDile GöreBölüme GöreKategoriye GöreYayıncıya GöreErişim ŞekliKurum Yazarına Göre

Hesabım

GirişKayıt

DSpace software copyright © 2002-2015  DuraSpace
İletişim | Geri Bildirim
Theme by 
@mire NV
 

 


|| Politika || Rehber|| Yönerge || Kütüphane || Muğla Sıtkı Koçman Üniversitesi || OAI-PMH ||

Muğla Sıtkı Koçman Üniversitesi, Muğla, Türkiye
İçerikte herhangi bir hata görürseniz, lütfen bildiriniz:

Creative Commons License
Muğla Sıtkı Koçman Üniversitesi Institutional Repository is licensed under a Creative Commons Attribution-NonCommercial-NoDerivs 4.0 Unported License..

DSpace@Muğla:


DSpace 6.2

tarafından İdeal DSpace hizmetleri çerçevesinde özelleştirilerek kurulmuştur.