Advanced exergoeconomic analysis with using modified productive structure analysis: An application for a real gas turbine cycle

Thumbnail

Göster/Aç

Tam metin / Full Text (2.104Mb)

Tarih

2021

Yazar

Uysal, Cüneyt
Keçebaş, Ali

Üst veri

Tüm öğe kaydını göster

Künye

Uysal C, Keçebaş A. Advanced exergoeconomic analysis with using modified productive structure analysis: an application for a real gas turbine cycle. Energy 2021:120085. doi:10.1016/j.energy.2021.120085.

Özet

In this study, advanced exergoeconomic analysis is performed for a gas turbine cycle located in Inchon/ South Korea. In addition, an approach combining advanced exergy analysis with modified productive structure analysis is applied to the system and the results are compared. Both methods showed that higher part of exergy destruction cost rate for overall system was unavoidable. The investment cost rate of system equipment was also unavoidable. Avoidable exergy destruction cost rate was higher than unavoidable part only for gas turbine. The exergy destruction cost rates obtained with approach are considerably lower than the results obtained with the advanced exergoeconomic analysis. This situation affected the strategies developed to obtain a cost-effective system for gas turbine. Advanced exergoeconomic analysis proposed reducing the exergy destruction cost rate for gas turbine. However, for gas turbine, the approach proposed reducing the investment cost rate. The sum of exergy destruction cost rate of system equipment was higher than that of overall system in advanced exergoeconomic analysis. However, the exergy destruction cost rate of overall system was equal to the sum of exergy destruction cost rate of system equipment in the approach. Finally, it can be concluded that the results obtained with the approach were more compatible.

Kaynak

Energy

Cilt

223

Bağlantı

https://doi.org/10.1016/j.energy.2021.120085
https://hdl.handle.net/20.500.12809/9226

Koleksiyonlar

  • Enerji Sistemleri Mühendisliği Bölümü Koleksiyonu [104]
  • WoS İndeksli Yayınlar Koleksiyonu [6466]



DSpace software copyright © 2002-2015  DuraSpace
İletişim | Geri Bildirim
Theme by 
@mire NV
 

 




| Politika | Rehber | İletişim |

DSpace@Muğla

by OpenAIRE
Gelişmiş Arama

sherpa/romeo

Göz at

Tüm DSpaceBölümler & KoleksiyonlarTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTüre GöreDile GöreBölüme GöreKategoriye GöreYayıncıya GöreErişim ŞekliKurum Yazarına GöreBu KoleksiyonTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTüre GöreDile GöreBölüme GöreKategoriye GöreYayıncıya GöreErişim ŞekliKurum Yazarına Göre

Hesabım

GirişKayıt

DSpace software copyright © 2002-2015  DuraSpace
İletişim | Geri Bildirim
Theme by 
@mire NV
 

 


|| Politika || Rehber|| Yönerge || Kütüphane || Muğla Sıtkı Koçman Üniversitesi || OAI-PMH ||

Muğla Sıtkı Koçman Üniversitesi, Muğla, Türkiye
İçerikte herhangi bir hata görürseniz, lütfen bildiriniz:

Creative Commons License
Muğla Sıtkı Koçman Üniversitesi Institutional Repository is licensed under a Creative Commons Attribution-NonCommercial-NoDerivs 4.0 Unported License..

DSpace@Muğla:


DSpace 6.2

tarafından İdeal DSpace hizmetleri çerçevesinde özelleştirilerek kurulmuştur.