Thermodynamic evaluation of a waste gas-fired steam power plant in an iron and steel facility using enhanced exergy analysis

Thumbnail

View/Open

Tam metin / Full text (548.0Kb)

Date

2019

Author

Yılmaz, Kadir
Kayfeci, Muhammet
Kecebaş, Ali

Metadata

Show full item record

Abstract

Since the industrial revolution to nowadays, many waste gases have been produced in iron-steel facilities. These gases increased the amount of energy consumption and risky by CO2 emissions. For these reasons, the useful waste gases, energy saving and decreased emissions technology are made. In this study, a collection of real operating data has been performed in an existing steam power plant using the useful waste gas that has occurred in iron and steel production facilities according to their nature, traditional and enhanced exergy analyses of it. The thermodynamic performance of the system is evaluated by improvement potential of the system components and by the interaction between the components. Useful waste gases produced in the facility consist of blast furnace gas, coke oven gas and converter gas. These gases are used for boosting the pressure and temperature of the circulation water by means of the heat of the exhaust gas produced by burning them at the steam-powered Rankine cycle's boiler and its subcomponents. The results of the study showed that the traditional and the enhanced exergy efficiencies of the system are respectively 60.7% and 83.7%. Potential improvement of the system and the interaction between the components are determined as 24.8% (low) and 74.5% (high). System components with improvement priority are condenser; combustion chamber, turbine, first super-heater and economizer at the traditional exergy analysis; whereas a combustion chamber, turbine, first superheater, economizer and second super-heater at the enhanced exergy analysis. Thus, as a similar result to those for all conversion thermal systems, combustion chamber is a component that always needs to be improved. (C) 2018 Elsevier Ltd. All rights reserved.

Source

Energy

Volume

169

URI

https://doi.org/10.1016/j.energy.2018.12.007
https://hdl.handle.net/20.500.12809/1093

Collections

  • Enerji Sistemleri Mühendisliği Bölümü Koleksiyonu [104]
  • Scopus İndeksli Yayınlar Koleksiyonu [6219]
  • WoS İndeksli Yayınlar Koleksiyonu [6466]



DSpace software copyright © 2002-2015  DuraSpace
Contact Us | Send Feedback
Theme by 
@mire NV
 

 




| Policy | Guide | Contact |

DSpace@Muğla

by OpenAIRE
Advanced Search

sherpa/romeo

Browse

All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsTypeLanguageDepartmentCategoryPublisherAccess TypeInstitution AuthorThis CollectionBy Issue DateAuthorsTitlesSubjectsTypeLanguageDepartmentCategoryPublisherAccess TypeInstitution Author

My Account

LoginRegister

DSpace software copyright © 2002-2015  DuraSpace
Contact Us | Send Feedback
Theme by 
@mire NV
 

 


|| Policy || Guide|| Instruction || Library || Muğla Sıtkı Koçman University || OAI-PMH ||

Muğla Sıtkı Koçman University, Muğla, Turkey
If you find any errors in content, please contact:

Creative Commons License
Muğla Sıtkı Koçman University Institutional Repository is licensed under a Creative Commons Attribution-NonCommercial-NoDerivs 4.0 Unported License..

DSpace@Muğla:


DSpace 6.2

tarafından İdeal DSpace hizmetleri çerçevesinde özelleştirilerek kurulmuştur.